Thanks Bob, the next logging session will be setup as per your suggestion.
Now I'm logging with the counter in time interval, Rb 1 is the start, GPS is the stop and Rb2 is the ext reference. The pulses are 670mS apart now. Fabio. Bob Camp <[email protected]> ha scritto:
Hi Yes, I would run the FE5680 into the counter's frequency standard input.
For the "real data", you can set up the counter to start on the GPS pps and stop on the 10 MHz output from the FE5680. You will only have 100 ns of range. You can unscramble the data after the fact. If you don't want to unscramble things, divide the 10 MHz down to 100 Hz and put that into the stop channel. Lots of fun. Bob
---------------------------------------------------------------- This message was sent using IMP, the Internet Messaging Program. _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.