Thanks Bob, the next logging session will
be setup as per your suggestion.

Now I'm logging with the counter
in time interval, Rb 1 is the start,
GPS is the stop and Rb2 is the ext
reference. The pulses are 670mS apart now.

Fabio.

Bob Camp <[email protected]> ha scritto:

Hi

Yes, I would run the FE5680 into the counter's frequency standard input.


For the "real data", you can set up the counter to start on the GPS pps and
stop on the 10 MHz output from the FE5680. You will only have 100 ns of
range. You can unscramble the data after the fact. If you don't want to
unscramble things, divide the 10 MHz down to 100 Hz and put that into the
stop channel.

Lots of fun.

Bob


----------------------------------------------------------------