Claude

Are you using the same software on the same computer platform for the whole time?

By example I have a Z3801 which works sometimes under Z38xx and sometimes not, while SATSTAT works all the time. I did find some flaky things going on with the software and was finding that I had to close Z38xx and reopen it after every command to change something?

Dave


On 1/26/2016 11:39 AM, [email protected] wrote:
Hello list !

I have a HP 58503A who  worked fine for two years.
After a short power cut, it does not lock on GPS. I tried some commandsn  
including :SYST:PRESET but nothing works

Here's a :SYSTEM:STATUS ? after the PRESET and after waiting a few hours :


------------------------------- Receiver Status -------------------------------

SYNCHRONIZATION ........................................... [ Outputs Invalid ]
SmartClock Mode ___________________________   Reference Outputs _______________
    Locked                                     TFOM     9             FFOM     3
    Recovery                                   1PPS TI  --
    Holdover                                   HOLD THR 1.000 us
Power-up: GPS acquisition                  Holdover Uncertainty ____________
                                               Predict  --

ACQUISITION .............................................. [ GPS 1PPS Invalid ]
Tracking: 0 ____   Not Tracking: 6 ________   Time ____________________________
                    PRN  El  Az                UTC      16:06:43 [?] 29 Feb 2016
                    * 1  -- ---                GPS 1PPS Invalid: not tracking
                    * 6  -- ---                ANT DLY  0 ns
                    * 9  -- ---                Position ________________________
                    *14  -- ---                MODE     Survey:      0% complete
                    *22  -- ---                         Suspended: track <4 sats
                    *24  -- ---                INIT LAT N 596:30:43.423
                                               INIT LON E 596:31:10.845
ELEV MASK 10 deg   *attempting to track                      +21474708.00 m  
(MSL)
HEALTH MONITOR ......................................................... [ OK ]
Self Test: OK    Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK

I tried to set the date with :GPS:INIT:DATE 2016,01,26 but this command has no 
effect.

Setting the LAT and LON with :GPS:POS «myposition» works.

------------------------------- Receiver Status -------------------------------
SYNCHRONIZATION ........................................... [ Outputs Invalid ]
SmartClock Mode ___________________________   Reference Outputs _______________
    Locked                                     TFOM     9             FFOM     3
    Recovery                                   1PPS TI  --
    Holdover                                   HOLD THR 1.000 us
Power-up: GPS acquisition                  Holdover Uncertainty ____________
                                               Predict  --
ACQUISITION .............................................. [ GPS 1PPS Invalid ]
Tracking: 0 ____   Not Tracking: 6 ________   Time ____________________________
                    PRN  El  Az                UTC      02:58:13 [?] 24 Mar 2016
                    * 3  -- ---                GPS 1PPS Invalid: not tracking
                    * 4  -- ---                ANT DLY  0 ns
                    * 8  -- ---                Position ________________________
                    * 9  -- ---                MODE     Hold
                    *23  -- ---
                    *29  -- ---                LAT      N    blah blah
                                               LON      E    blah blah
ELEV MASK 10 deg   *attempting to track       HGT              +194.57 m  (MSL)
HEALTH MONITOR ......................................................... [ OK ]
Self Test: OK    Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK


But the unit is still not tracking, it sees the birds because the PRN are 
changing but
does not calculate the "El" and "Az"  ...

Here is the output of  :DIAGnostic:LOG:READ:ALL?

Log 001:20160122.00:00:00:  Log cleared
Log 002:20160122.00:00:00:  System preset
Log 003:20160122.00:00:35:  Self-test failed
Log 004:20160122.00:12:38:  Position hold mode started

As you can see, the date is 2016-01-22, it's the date when the power cut 
happened .

And when I run  :GPSYSTEM:POSITION:SURVEY ONCE, I get the same first status 
with crazy
lattidude and longitude.


Finally a self test *TST? gives +0 and the ALARM LED and the LOCK LED are off.

I've tried with a second antenna and have the same problem :-(

Can someone give me an advice for this problem ? The receiver looks dead, no ?

Thanks in advance,


Claude
_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.



--
Dave
[email protected]
www.ArtekManuals.com


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus

_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to