-------- In message <[email protected]>, jimlux writes:
>The conceptual idea being similar to setting a PLL Loop filter bandwidth >such that the reference noise (multiplied up) and the VCO noise are the >same at that point? I tried that, and got absolutely no where, because the noise-spectra are not flat or even comparable. Instead started to look at the time distribution of the zero-crossings of the residual low-pass filtered phase error, and that has given me much better results all in all. -- Poul-Henning Kamp | UNIX since Zilog Zeus 3.20 [email protected] | TCP/IP since RFC 956 FreeBSD committer | BSD since 4.3-tahoe Never attribute to malice what can adequately be explained by incompetence. _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to http://lists.febo.com/mailman/listinfo/time-nuts_lists.febo.com and follow the instructions there.