In message <[email protected]>, jimlux writes:

>The conceptual idea being similar to setting a PLL Loop filter bandwidth 
>such that the reference noise (multiplied up) and the VCO noise are the 
>same at that point?

I tried that, and got absolutely no where, because the noise-spectra
are not flat or even comparable.

Instead started to look at the time distribution of the zero-crossings
of the residual low-pass filtered phase error, and that has given me
much better results all in all.

-- 
Poul-Henning Kamp       | UNIX since Zilog Zeus 3.20
[email protected]         | TCP/IP since RFC 956
FreeBSD committer       | BSD since 4.3-tahoe    
Never attribute to malice what can adequately be explained by incompetence.