On Feb 7, 2006, at 1:25 PM, John Pettitt wrote:
I'm seeing similar spikes for my servers - one of which is stratum 1
varies by +/- 40us typically. I put it down to the monitoring server
either having a really bad time source or an overloaded net
connection.
- Where is the monitoring server and how is it connected?
Los Angeles, connected via internap.
Any spikes at least up to ~100ms can easily be attributed to network
trouble. Don't read too much into the offset graphs on lower numbers.
If/when we want to measure the offset more accurately from the
monitoring station I'll setup several of them and have them use ntpd
rather than the simplistic sntp client.
- ask
--
http://www.askbjoernhansen.com/
_______________________________________________
timekeepers mailing list
[email protected]