I'm not aware of the fact that Switzerland will adopt TBR21.
It's not in the EC. Does anybody have other info on this?

Best regards, Rene

----------
From:   [email protected] on behalf of Duane J Marcroft
Sent:   Friday, October 04, 1996 8:12 AM
To:     [email protected]
Subject:        Metering Tones Under TBR 21

Treggers,

I need an interpreter.  I've read the paragraph below from prTBR 21 and to
me it's a bit vague.  I assume metering tones will still be mandatory in
Switzerland after the approval TBR 21?  I don't see how there going away
just because TBR 21 is approved.  I have a client insisting the filtering
in Switzerland is no longer needed.  I don't believe it.  Can someone 
please read the paragraph and let know the correct answer? 

My in house English major also thinks the statement is a bit vague.

It's from TBR 21 Scope section (page 7)  It states the following: 

"This TBR covers TE which is capable of originating a circuit-switched
call using Dual Tone Mult Frequency (DTMF) signalling and/or receiving an
incoming circuit-switched call.  Other signalling methods (e.g. 
disconnect signalling) if provided in the terminal and intended to be used
in certain European countries are subject to the appropriate national
Regulations in respect of that feature, in addition to this TBR.  Also
signaling for supplementary features (e.g. register recall, reception of
metering pulses from network) if provided in the terminal, and intended to
be used in certain European countries, are subjected to the appropriate
National Regulations."

Thanks in advance.

Duane


Reply via email to