Hi! Treggers:

The CS-03 requirements are :
For all operating conditions of the TE, the maximum power shall not   
exceed the following when averaged over any 3-s interval:
(a)  0 dBm when DTMF is used for network control;
(b)  0 dBm when DTMF is used for end-to-end signalling via manual entry   
of a keypad or repertory dialler. The term "repertory dialler" does not   
accommodate devices capable of generating more than 40 DTMF digits per   
manual keystroke.
All other requirements such as tone specifications, maximum differences   
in power levels, etc. have been removed when the new Issue (Issue 8) is   
published June 15, 1996 and become effective August 14, 1996.

Merry Christmas and Happy New Year!!

Henry Mar
Industry Canada
[email protected]

 ----------
From:  treg[SMTP:[email protected]]
Sent:  Tuesday, December 17, 1996 3:12 PM
To:  treg
Subject: Re: US DTMF Requirements

     Peter,
       

     The FCC Part 68 DTMF requirements  are not very extensive.
     Power, with three second averaging, must not be greater than 0 dBm
     into 600 Ohms, (or .775 V)
       

     There are no frequency or  twist specifications.

    Industry Canada CS-03 has requirements, I believe they are the same   
as
TIA-496.

Eric Petitpierre
Pulsecom
Herndon, VA
[email protected]


______________________________ Reply Separator
_________________________________
Subject: BOUNCE [email protected]: Non-member submission from ["Pete
Author:  [email protected] at SMTP
List-Post: [email protected]
Date:    12/17/96 1:39 PM


From: "Pete Van Raalte" <[email protected]>
To: [email protected]
List-Post: [email protected]
Date:          Tue, 17 Dec 1996 10:11:53 EST
Subject: US DTMF Requirements

TREG'ers,

I am looking for specs on DTMF frequency, amplitude, and twist in the
US.  I have found one listing in ANSI/EIA/TIA-496-A-1989, but I have
not found anything in FCC requirements.

Is DTMF specified somewhere in the bowels of Part 68?

advTHANKSance

Pete
 --------------------------------------------------------------------------  
 --
Peter Van Raalte  |   Email: [email protected]
Compliance Engineer  |
V-Band Corporation  |   Phone: 914-789-5117
565 Taxter Road          |
Elmsford NY 10523  |   FAX:   914-347-3432
 --------------------------------------------------------------------------  
 -


Reply via email to