On 2018/2/28 0:55, Mariano Coromac wrote:
Hmmm, by sequential number do you mean the Specification Version? This
one is correct.
Here's my eMMC info.
=> mmc info
Device: sdio-host@a0000000
Manufacturer ID: eb
OEM: 10d
Name: eMMC
Tran Speed: 52000000
Rd Block Len: 512
MMC version 5.0
High Capacity: Yes
Capacity: 3.6 GiB
Bus Width: 4-bit
Erase Group Size: 512 KiB
HC WP Group Size: 8 MiB
User Capacity: 3.6 GiB
Boot Capacity: 2 MiB ENH
RPMB Capacity: 512 KiB ENH
This is right, did you try the command,
=> mmc read addr blk# cnt
does it work?
Best Regards,
Wenyou Yang