Hi Tim,

On Mon, Oct 3, 2022 at 8:39 PM Tim Harvey <thar...@gateworks.com> wrote:

> Fabio,
>
> I'm not sure why your configuration is behaving differently and think
> you'll have to instrument code to help understand it.
>
> Here is the chain of events I see on my imx6q fec <-> mv88e6085 configuration:

The switch I am using is a mv88e6320.

I instrumented the code a bit and I notice that I am not able to read
the switch ID.

mv88e6xxx_get_switch_id() fails because mv88e6xxx_port_read() returns 0xffff.

I am investigating this failure.

Thanks