Adrian, I'm surprised you haven't seen it (not that I'd wish the subsequent reconciliation and explanation on anyone) If you're interested here's an example :
>ED BP TWZ 6 lines long. ----: P 0001: NET = 294987.31 0002: VAT = 51622.78 0003: TOT = NET + VAT 0004: IF TOT EQ 346610.09 THEN PRINT 'Equal' 0005: ELSE PRINT 'Wide-zero problem ?' 0006: END Bottom at line 6. ----: Q >RUN BP TWZ Wide-zero problem ? I've seen it 3 times in the last 3 years, this is the simplest example yet. -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Behalf Of Adrian Matthews I'm obviously missing something here. Our system processes thousands of financial transactions a day with most calculations being done to several places. We've never had a need to change the Wide0 settings from the default.... -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of [EMAIL PROTECTED] Goo'day, We have *always* (since 1998, anyway, 9.3?? on NT) changed WideZero to 0X3eb000000. This way we *always* get 1-1=0 .... ------- u2-users mailing list [EMAIL PROTECTED] To unsubscribe please visit http://listserver.u2ug.org/