Hi Peter,
Assuming that you are talking about UniVerse Basic object code and not the
UV executable itself, this is no problem. We do it all the time, building on
one system and shipping to others.
So long as you are not using new features that are not on the target system
and the byte ordering is the same, just copy the files across.
If the byte ordering is different, UV will do an on-the-fly conversion as it
loads the program, however, this could have a small performance impact if
the program is loaded many times. Use of the fnuxi or format.conv tools from
the o/s level will convert the code on disk.
Martin Phillips
Ladybridge Systems Ltd
17b Coldstream Lane, Hardingstone, Northampton, NN4 6DB
+44-(0)1604-709200
-------
u2-users mailing list
[email protected]