You should probably just change the program so if you're not going to
WRITE, do a RELEASE!
-Dianne
Steve Ferries wrote:
Hi All,
We had some excitement today when we ran a program with READU, with the
associated WRITE commented out. In no time at all (these RS6000s are
fast!), the system froze. I had a login and some UniVerse commands
worked, but others did not. LIST.READU showed one user with thousands of
locks and that is how we identified the program.
Can someone tell me what the maximum of locks allowed is, or what the
size of the lock table is? We don't want to increase it (nor do we want
to put a count in and unleash the program a second time!).
Thanks
Steve
Steve Ferries
(416) 774 4250
[EMAIL PROTECTED]
-------
u2-users mailing list