You need UV/Net.  There are two solutions.

1. Wherever you want to run the application, set up VOC entries to point to the 
remote part files, using hostname!pathname syntax in the DATA.FILE (field #2) 
entry.  This will be picked up by UV/Net software and afford remote access to 
the part files.  Then build a (local) Distributed File based on the part file 
records in VOC as usual.

2. Set up remote accounts in UV.ACCOUNT, again using the hostname!pathname 
syntax.  Wherever you want to run the application, set up regular Q-pointers to 
the files in the remote accounts.  Then build a (local) Distributed File based 
on the part file records in VOC as usual.
-------