I just upgraded a backhaul link from old airgrid M5s to Powerbeam M5s
running XW 5.6.9. This link runs from a main tower with a router on an OSPF
ring to a remote repeater which is just bridged back to the main tower. The
main tower has a mikrotik doing DHCP relay back to our powercode BMU DHCP
server. The link has WDS enabled to make it transparent.

After upgrading the link, I have a problem where after some time, a few
hours or a few days, the CPEs past the link (ubnt and ePMP) cannot renew
their DHCP lease. Rebooting the backhaul radios fixes it. The remote tower
just has a dumb switch and has been in service and stable for years with
the previous airgrid link. The link has good signal and no signs of
interference. Nothing unusual shows up in the logs on either end .

Anyone seen this behavior or any ideas?
_______________________________________________
Ubnt_users mailing list
[email protected]
http://lists.wispa.org/mailman/listinfo/ubnt_users

Reply via email to