Either a telco rectifier pack for official -48v dc. I guess you might already 
have them or there are a gazillion on eblag.

Or if you  are happy with 24v dc, something like this:

http://www.ebay.co.uk/itm/24V-DC-3-AMP-2-1mm-POWER-SUPPLY-ADAPTOR-CCTV-CAMERA-3A-/321204593187?pt=UK_CCTV&hash=item4ac9492223

Amphenol connectors are available in 3 and 6 way in RS/Maplin/CPC/a.n.other if 
you are happy to chop the lead up and make it yourself.

If you have a rummage, a few laptops run on 24v dc so you might just have 
something knocking about there already.

Peter Knapp


From: uknof [mailto:[email protected]] On Behalf Of Richard 
Savage
Sent: 14 August 2014 13:47
To: '[email protected]'
Subject: [uknof] Lab DC Power Supply Cisco ASR901

Hi

I am testing some new Cisco ASR901’s and need to find a suitable DC power 
supply that will power them up in a lab environment.  The ASR 901-12C-F-D says 
that it will accept:

1 GE models:
● DC-input voltage rating: 24 VDC, -48 VDC, -60 VDC
● DC-input current rating: 2.5A maximum for non- TDM variants and 3.0A maximum 
for TDM variants

Power connector
6-position 2-tier stacked connector comprising two feeds, A and B DC power 
(AMPHENOL ELVA06100), and 3‑position mating connectors for each feed (AMPHENOL 
ELVP03100)

Does anyone have any suggestions to a Lab DC power supply?

Thanks

Rich

Richard Savage
Senior Network Engineer
Timico Partners
Carnac Lodge, Cams Estate, Fareham, Hampshire, PO16 8UJ

Web: www.partners.timico.co.uk<http://www.partners.timico.co.uk/>

Timico Partner Services Limited. Co.Reg. No: 03128506
[Timico]<http://www.partners.timico.co.uk/>


This e-mail is sent on behalf of Timico Partner Services Limited, a company 
registered in England and Wales, registered number 03128506, registered office 
Beacon Hill Park, Newark, Nottinghamshire, NG24 2TN and regulated by Ofcom. The 
information in this e-mail is confidential and is intended solely for the use 
of that individual or entity to which it is addressed. Unauthorised use, 
dissemination, distribution, publication or copying of this communication is 
strictly prohibited. If you receive this in error, please notify us by email to 
[email protected]<mailto:[email protected]> and delete any copies. For 
information about how we process data and monitor communications please see our 
privacy 
statement<http://www.timico.co.uk/downloads/terms/Privacy_Statement.pdf>.

Reply via email to