Hi,

EXECUTOR_SIGNAL_ESCALATION_TIMEOUT is set to 3 seconds, hard-coded.

EXECUTOR_SHUTDOWN_GRACE_PERIOD  has a default of 5, and can be configured

docker_stop_timeout - default of 0, configurable as well


I am running a jobsystem app that needs to clean up and write back some data 
before it dies.  Its run by mesos through docker and, preferably, it needs more 
than 3 seconds (15 would be safe)


For testing, I have set:


docker_stop_timeout = 20 secs


and


executor_shutdown_grace_period = 30secs


How do the above two play with EXECUTOR_SIGNAL_ESCALATION_TIMEOUT (which is 3 
seconds) ? Could someone explain the logic and order in which those params are 
enforced?