+1, I'd like to know that also.

2015-06-01 23:36 GMT+08:00 Maciej Strzelecki <
[email protected]>:

>  Hi,
>
>
>  EXECUTOR_SIGNAL_ESCALATION_TIMEOUT is set to 3 seconds, hard-coded.
>
> EXECUTOR_SHUTDOWN_GRACE_PERIOD  has a default of 5, and can be configured
>
> docker_stop_timeout - default of 0, configurable as well
>
>
>  I am running a jobsystem app that needs to clean up and write back some
> data before it dies.  Its run by mesos through docker and, preferably, it
> needs more than 3 seconds (15 would be safe)
>
>
>  For testing, I have set:
>
>
>  docker_stop_timeout = 20 secs
>
>
>  and
>
>
>  executor_shutdown_grace_period = 30secs
>
>
>  How do the above two play with EXECUTOR_SIGNAL_ESCALATION_TIMEOUT (which
> is 3 seconds) ? Could someone explain the logic and order in which those
> params are enforced?
>
>
>
>
>   Maciej Strzelecki
> Operations Engineer
> Tel: +49 30 6098381-50
> Fax: +49 851-213728-88
> E-mail: [email protected]
> www.crealytics.com
> blog.crealytics.com
>
> crealytics GmbH - Semantic PPC Advertising Technology
>
> Brunngasse 1 - 94032 Passau - Germany
> Oranienstraße 185 - 10999 Berlin - Germany
>
> Managing directors: Andreas Reiffen, Christof König, Dr. Markus Kurch
> Register court: Amtsgericht Passau, HRB 7466
> Geschäftsführer: Andreas Reiffen, Christof König, Daniel Trost
> Reg.-Gericht: Amtsgericht Passau, HRB 7466
>
>