Hi Maciej, I apologize the confusion, let me see if I can clarify (inlined)
On 1 June 2015 at 19:42, zhou weitao <[email protected]> wrote: > +1, I'd like to know that also. > > 2015-06-01 23:36 GMT+08:00 Maciej Strzelecki < > [email protected]>: > >> Hi, >> >> >> EXECUTOR_SIGNAL_ESCALATION_TIMEOUT is set to 3 seconds, hard-coded. >> > This is specifically for the command executor which, first off, tries to send SIGTERM. If nothing happens in EXECUTOR_SIGNAL_ESCALATION_TIMEOUT, a SIGKILL is sent. > EXECUTOR_SHUTDOWN_GRACE_PERIOD has a default of 5, and can be configured >> > This applies for all executors using the mesos executor driver (which is the majority) and wraps the 'kill cycle' in the command executor (which is around 3 seconds). > docker_stop_timeout - default of 0, configurable as well >> >> >> I am running a jobsystem app that needs to clean up and write back some >> data before it dies. Its run by mesos through docker and, preferably, it >> needs more than 3 seconds (15 would be safe) >> >> >> For testing, I have set: >> >> >> docker_stop_timeout = 20 secs >> >> >> and >> >> >> executor_shutdown_grace_period = 30secs >> >> >> How do the above two play with EXECUTOR_SIGNAL_ESCALATION_TIMEOUT (which >> is 3 seconds) ? Could someone explain the logic and order in which those >> params are enforced? >> >> >> >> >> Maciej Strzelecki >> Operations Engineer >> Tel: +49 30 6098381-50 >> Fax: +49 851-213728-88 >> E-mail: [email protected] >> www.crealytics.com >> blog.crealytics.com >> >> crealytics GmbH - Semantic PPC Advertising Technology >> >> Brunngasse 1 - 94032 Passau - Germany >> Oranienstraße 185 - 10999 Berlin - Germany >> >> Managing directors: Andreas Reiffen, Christof König, Dr. Markus Kurch >> Register court: Amtsgericht Passau, HRB 7466 >> Geschäftsführer: Andreas Reiffen, Christof König, Daniel Trost >> Reg.-Gericht: Amtsgericht Passau, HRB 7466 >> >> > Hope this helps, Niklas