As I mentioned in a previous e-mail we had a planned outage recently and our grid engine config was corrupted when we tried to restart due to filesystem problems.
We managed to restore the grid engine config from backup while retaining all the queued jobs. But before allowing them on we wanted to test the system. To facilitate this I used qconf -mconf and set projects to a project that only the system administration team were members of. Despite this when we powered on the worker nodes lots of regular user jobs started on the nodes as they come up (we have initial_state enabled on all our queues). Is this a known bug or have I misunderstood the use of the projects setting in sge_conf (it occurs to me it might only control job submission not running)? Still using 6.2u3. William _______________________________________________ users mailing list [email protected] https://gridengine.org/mailman/listinfo/users