As I mentioned in a previous e-mail we had a planned outage recently
and our grid engine config was corrupted when we tried to restart due
to filesystem problems.

We managed to restore the grid engine config from backup while
retaining all the queued jobs.  But before allowing them on we wanted
to test the system.

To facilitate this I used qconf -mconf and set projects to a project
that only the system administration team were members of.

Despite this when we powered on the worker nodes lots of regular user
jobs started on the nodes as they come up (we have initial_state
enabled on all our queues).

Is this a known bug or have I misunderstood the use of the projects
setting in sge_conf (it occurs to me it might only control job
submission not running)?

Still using 6.2u3.

William
_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users

Reply via email to