sorry, wrong link, correct: https://redmine.kannel.org/projects/kannel
2012/6/26 spameden <[email protected]> > Yes, it seems to be a bug, please submit to > http://redmine.kannel.org/project/kannel. > > > 2012/6/25 vouk voukam voukam <[email protected]> > >> That's actually a bug. >> When ever you have a comment after a value at your cnf file this is >> interpreted as a value.i.e: >> sms-center= xxxxxxxxxx #SMS center >> it will be parsed as xxxxxxxxxx #SMS center >> >> ------------------------------ >> From: [email protected] >> To: [email protected] >> Subject: RE: Huawei E220 Generic error: ERROR - Initialization of device >> failed. >> Date: Mon, 25 Jun 2012 19:53:02 +0000 >> CC: [email protected] >> >> >> Thanks alvaro that was a useful tip i should have tought >> From kannel.log: >> 2012-06-25 21:32:07 [3926] [6] INFO: AT2[Huawei-e220]: speed set to 115200 >> 2012-06-25 21:32:07 [3926] [6] DEBUG: AT2[Huawei-e220]: --> ATZ^M >> 2012-06-25 21:32:07 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- OK >> 2012-06-25 21:32:07 [3926] [6] DEBUG: AT2[Huawei-e220]: --> AT^M >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- AT >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- OK >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: --> AT&F^M >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- AT&F >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- OK >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: --> ATE0^M >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- ATE0 >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- OK >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: --> AT+IFC=2,2^M; >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- OK >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: --> AT+CPIN?^M >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- +CPIN: READY >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- OK >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: --> >> AT+CSCA="xxxxxxxxxxxx #SIM Number"^M >> 2012-06-25 21:32:08 [3926] [6] DEBUG: AT2[Huawei-e220]: <-- ERROR >> 2012-06-25 21:32:08 [3926] [6] ERROR: AT2[Huawei-e220]: Generic error: >> ERROR >> 2012-06-25 21:32:08 [3926] [6] ERROR: AT2[Huawei-e220]: Initialization of >> device failed. >> 2012-06-25 21:32:08 [3926] [6] INFO: AT2[Huawei-e220]: Closing device >> >> where xxxxxxxxxxx is the value of the sms-center field. >> After the value at my configuration i had a comment like this #SIM Number >> I realized that the comment was part of the number so i remove the >> comment and everything work properly,This might be a possible bug(???) >> >> bearerbox started properly i send an sms from the http interface and i >> got this: >> 2012-06-25 21:48:29 [4387] [6] INFO: AT2[Huawei-e220]: AT SMSC >> successfully opened. >> 2012-06-25 21:48:39 [4387] [5] INFO: Client connected from <127.0.0.1> >> 2012-06-25 21:48:52 [4387] [6] ERROR: AT2[Huawei-e220]: CMS ERROR: +CMS >> ERROR: 500 >> 2012-06-25 21:48:52 [4387] [6] ERROR: AT2[Huawei-e220]: CMS ERROR: >> Unknown error. -> maybe Sim storage is full? I'll have a look at it. (500) >> >> and this at the web page:0: Accepted for delivery >> >> As an sms-center i hadthe sms center from my mobile operator i then >> changed this to my SIM number but the same is happening. >> >> >> >> >> > Date: Mon, 25 Jun 2012 14:22:39 -0500 >> > Subject: Re: Huawei E220 Generic error: ERROR - Initialization of >> device failed. >> > From: [email protected] >> > To: [email protected] >> > CC: [email protected] >> > >> > Can you set log level to debug? ie = 0? >> > >> > So we can have more details on the problem? >> > >> > Regards >> > >> > Alvaro >> > >> > On 6/25/12, vouk voukam voukam <[email protected]> wrote: >> > > >> > > I added as shown in the configuration section of modems below. The >> same >> > > generic errors i get from bearerbox... >> > > # Huawei E220 #It should be changed to work for your mobile group = >> modems >> > > id = huawei_e220 name = "Huawei_E220" detect-string = "huawei" >> #init-string >> > > = "ATZ" #init-string = "ATQ0 V1 E1 S0=0 &C1 &D2 +FCLASS=0" >> init-string = >> > > "AT+CMEE=1" #init-string = "AT+CNMI=1,2,0,0,1" #init-string = >> > > "AT+CNMI=2,1,2,2,0" message-storage=sm speed=9600 >> > > >> > >> Date: Mon, 25 Jun 2012 12:35:13 -0500 >> > >> Subject: Re: Huawei E220 Generic error: ERROR - Initialization of >> device >> > >> failed. >> > >> From: [email protected] >> > >> To: [email protected] >> > >> CC: [email protected] >> > >> >> > >> can you add "+CMEE=1" or "+CMEE=2" to your modem init string? It >> might >> > >> give you more detail on "generic error" message. >> > >> >> > >> Regards >> > >> >> > >> Alvaro >> > >> >> > >> On 6/25/12, vouk voukam voukam <[email protected]> wrote: >> > >> > >> > >> > I gave full access to USB01 chmod 777 /dev/ttyUSB0 and to >> > >> > /devttyUSB1The >> > >> > same error occurs >> > >> >> Date: Mon, 25 Jun 2012 10:39:49 -0500 >> > >> >> Subject: Re: Huawei E220 Generic error: ERROR - Initialization of >> > >> >> device >> > >> >> failed. >> > >> >> From: [email protected] >> > >> >> To: [email protected] >> > >> >> CC: [email protected] >> > >> >> >> > >> >> check read/write permissions for kannel user into /dev/ttyUSB01 >> > >> >> >> > >> >> Regards >> > >> >> >> > >> >> Alvaro >> > >> >> >> > >> >> On 6/25/12, vouk voukam voukam <[email protected]> wrote: >> > >> >> > >> > >> >> > I want to setup Kannel in my Ubuntu machine. I have a Huawei >> e220 >> > >> >> > modem >> > >> >> > which is equipped with a SIM card and i have tested through >> minicom. >> > >> >> > It >> > >> >> > can >> > >> >> > successfully reads and sends SMS messages to phone numbers.This >> is >> > >> >> > my >> > >> >> > configuration: >> > >> >> > >> > >> >> > group = core admin-port = 13002 smsbox-port = 13003 >> > >> >> > admin-password = bar box-deny-ip = "*.*.*.*" box-allow-ip = >> > >> >> > "127.0.0.1" group = smsc smsc = at modemtype = huawei >> > >> >> > device >> > >> >> > = /dev/ttyUSB1 my-number = number sms-center = number #SIM >> > >> >> > Number >> > >> >> > my-number = number #SIM Number log-level = 1 group = >> > >> >> > modems >> > >> >> > id = huawei_e220 name = "Huawei_E220" detect-string = "huawei" >> > >> >> > init-string = "ATZ" init-string = "ATQ0 V1 E1 S0=0 &C1 &D2 >> > >> >> > +FCLASS=0" >> > >> >> > message-storage=sm speed=9600 group = smsbox >> > >> >> > bearerbox-host >> > >> >> > = 127.0.0.1 sendsms-port = 13013 global-sender = numberThe >> > >> >> > init-strings have been taken from /etc/wvdial.confwhen i am >> starting >> > >> >> > bearerbox it seems that it is not starting correctly: >> > >> >> > 2012-06-25 16:56:36 [8531] [6] ERROR: AT2[Huawei-e220]: >> > >> >> > Initialization >> > >> >> > of >> > >> >> > device failed.2012-06-25 16:56:36 [8531] [6] INFO: >> AT2[Huawei-e220]: >> > >> >> > Closing >> > >> >> > device2012-06-25 16:56:36 [8531] [6] ERROR: AT2[Huawei-e220]: >> > >> >> > Couldn't >> > >> >> > connect (retrying in 10 seconds).2012-06-25 16:56:46 [8531] [6] >> > >> >> > INFO: >> > >> >> > AT2[Huawei-e220]: opening device2012-06-25 16:56:46 [8531] [6] >> INFO: >> > >> >> > AT2[Huawei-e220]: Logging in2012-06-25 16:56:46 [8531] [6] INFO: >> > >> >> > AT2[Huawei-e220]: init device2012-06-25 16:56:46 [8531] [6] >> INFO: >> > >> >> > AT2[Huawei-e220]: speed set to 1152002012-06-25 16:56:47 [8531] >> [6] >> > >> >> > ERROR: >> > >> >> > AT2[Huawei-e220]: Generic error: ERROR2012-06-25 16:56:47 >> [8531] [6] >> > >> >> > ERROR: >> > >> >> > AT2[Huawei-e220]: Initialization of device failed.2012-06-25 >> > >> >> > 16:56:47 >> > >> >> > [8531] >> > >> >> > [6] INFO: AT2[Huawei-e220]: Closing device2012-06-25 16:56:47 >> [8531] >> > >> >> > [6] >> > >> >> > ERROR: AT2[Huawei-e220]: Couldn't connect (retrying in 10 >> > >> >> > seconds).2012-06-25 16:56:57 [8531] [6] INFO: AT2[Huawei-e220]: >> > >> >> > opening >> > >> >> > device2012-06-25 16:56:57 [8531] [6] INFO: AT2[Huawei-e220]: >> Logging >> > >> >> > in2012-06-25 16:56:58 [8531] [6] INFO: AT2[Huawei-e220]: init >> > >> >> > device2012-06-25 16:56:58 [8531] [6] INFO: AT2[Huawei-e220]: >> speed >> > >> >> > set >> > >> >> > to >> > >> >> > 1152002012-06-25 16:56:58 [8531] [6] ERROR: AT2[Huawei-e220]: >> > >> >> > Generic >> > >> >> > error: >> > >> >> > ERROR2012-06-25 16:56:58 [8531] [6] ERROR: AT2[Huawei-e220]: >> > >> >> > Initialization >> > >> >> > of device failed.2012-06-25 16:56:58 [8531] [6] INFO: >> > >> >> > AT2[Huawei-e220]: >> > >> >> > Closing device2012-06-25 16:56:58 [8531] [6] ERROR: >> > >> >> > AT2[Huawei-e220]: >> > >> >> > Couldn't connect (retrying in 10 seconds).2012-06-25 16:57:08 >> [8531] >> > >> >> > [6] >> > >> >> > INFO: AT2[Huawei-e220]: opening device2012-06-25 16:57:08 >> [8531] [6] >> > >> >> > INFO: >> > >> >> > AT2[Huawei-e220]: Logging in2012-06-25 16:57:09 [8531] [6] INFO: >> > >> >> > AT2[Huawei-e220]: init device2012-06-25 16:57:09 [8531] [6] >> INFO: >> > >> >> > AT2[Huawei-e220]: speed set to 1152002012-06-25 16:57:10 [8531] >> [6] >> > >> >> > ERROR: >> > >> >> > AT2[Huawei-e220]: Generic error: ERROR2012-06-25 16:57:10 >> [8531] [6] >> > >> >> > ERROR: >> > >> >> > AT2[Huawei-e220]: Initialization of device failed.2012-06-25 >> > >> >> > 16:57:10 >> > >> >> > [8531] >> > >> >> > [6] INFO: AT2[Huawei-e220]: Closing device2012-06-25 16:57:10 >> [8531] >> > >> >> > [6] >> > >> >> > ERROR: AT2[Huawei-e220]: Couldn't connect (retrying in 10 >> > >> >> > seconds).2012-06-25 16:57:20 [8531] [6] INFO: AT2[Huawei-e220]: >> > >> >> > opening >> > >> >> > device2012-06-25 16:57:20 [8531] [6] INFO: AT2[Huawei-e220]: >> Logging >> > >> >> > in2012-06-25 16:57:20 [8531] [6] INFO: AT2[Huawei-e220]: init >> > >> >> > device2012-06-25 16:57:20 [8531] [6] INFO: AT2[Huawei-e220]: >> speed >> > >> >> > set >> > >> >> > to >> > >> >> > 1152002012-06-25 16:57:21 [8531] [6] ERROR: AT2[Huawei-e220]: >> > >> >> > Generic >> > >> >> > error: >> > >> >> > ERROR >> > >> >> > What am i doing wrong with the conf? >> > >> >> > >> > >> >> > >> > >> >> >> > >> >> >> > >> >> -- >> > >> >> >> |-----------------------------------------------------------------------------------------------------------------| >> > >> >> Envíe y Reciba Datos y mensajes de Texto (SMS) hacia y desde >> cualquier >> > >> >> celular y Nextel >> > >> >> en el Perú, México y en mas de 180 paises. Use aplicaciones 2 >> vias via >> > >> >> SMS y GPRS online >> > >> >> Visitenos en www.perusms.NET www.smsglobal.com.mx y >> > >> >> www.pravcom.com >> > >> > >> > >> >> > >> >> > >> -- >> > >> >> |-----------------------------------------------------------------------------------------------------------------| >> > >> Envíe y Reciba Datos y mensajes de Texto (SMS) hacia y desde >> cualquier >> > >> celular y Nextel >> > >> en el Perú, México y en mas de 180 paises. Use aplicaciones 2 vias >> via >> > >> SMS y GPRS online >> > >> Visitenos en www.perusms.NET www.smsglobal.com.mx y >> > >> www.pravcom.com >> > > >> > >> > >> > -- >> > >> |-----------------------------------------------------------------------------------------------------------------| >> > Envíe y Reciba Datos y mensajes de Texto (SMS) hacia y desde cualquier >> > celular y Nextel >> > en el Perú, México y en mas de 180 paises. Use aplicaciones 2 vias via >> > SMS y GPRS online >> > Visitenos en www.perusms.NET www.smsglobal.com.mx y >> > www.pravcom.com >> > >