Hi all,

I have come up with an unfortunate problem.  I had a working kannel
configuration with an operators SMSC, everything was working fine, then
lately they say that I am connecting to there interface using two
interfaces. They have now limited me to one, and my kannel logs receive an
error

SMSC rejected login to receive code 0x0000000d (bind failed)

I have configured kannel as a transceiver via transceiver-mode=true. I have
asked them to undue the interface limit whilst I re-configure my setup.

I checked out the connections to my server via lsof -i .... I noticed is
that bearerbox under transceiver-mode initiates two connections to SMSC,
which I suspect the mobile operator treats as two interfaces. So my
question is how do I get kannel to connect to SMSC via one TCP connection
in transceiver mode

Hope will get help

Regards

Reply via email to