Hi Jozef!

Many thanks for your reply! Just tested it and that is the case. Everything 
works when I remove the disabled processor.

Many thanks again & all the best

Valentina
________________________________
From: [email protected]
Sent: Wednesday, February 05, 2020 12:04
To: [email protected]
Subject: Re: NiFi import processor group created with previous NiFi version 
does not work


Hi Valentina,



has your template/canvas disabled processors? I’ve already faced a bug which 
caused the same error as yours.

https://issues.apache.org/jira/projects/NIFI/issues/NIFI-6958



Cheers Josef





From: Valentina Ivanova <[email protected]>
Reply to: "[email protected]" <[email protected]>
Date: Wednesday, 5 February 2020 at 11:10
To: "[email protected]" <[email protected]>
Subject: NiFi import processor group created with previous NiFi version does 
not work



Hi everyone!



We are investigating the following issue.

I have a dev NiFi instance with version 1.10.0 where I created a process group 
template with approximately 15 processors. I can upload that template to the 
production NiFi with version 1.11.0 and then start version control and commit 
it to the nifi registry.

However when I delete that template from the canvas and try to import it from 
the registry I get the following error message - No Processor with ID <SOME-ID> 
belongs to this Process Group.

If I create the processor group template in the production NiFi 1.11.0 then I 
can delete it and import it back to the canvas without issues.

Do you have any idea why this happens? Is this any versioning issues in 
connection to the NiFi processors? Help is very appreciated.



Thanks & all the  best



Valentina

Reply via email to