You say you're using the metric system. Is that METRIC? Or, METRICWX? If the former, your StdQC would eliminate any data that has more than 300 cm of rain in an archive period. Unless your archive period is unusually long, you could probably make it as little as 1 cm.
-tk On Fri, Dec 16, 2016 at 4:59 PM, Marc Aubry <[email protected]> wrote: > hi, > Is there not a faster way than rebuilding the all tables? > i have data from june 2014 in the database because i have imported the > data from my previous cumulus system. > it take a long time to rebuild the all daily summaries from a raspberry > just to correct one bad entries? > > is it enough to put max and min valuse in StdQC to avoid such problem? > mine look like that (metric system): > > *[StdQC]* > * [[MinMax]]* > * barometer = 900, 1100* > * outTemp = 10, 60* > * inTemp = 10, 60* > * outHumidity = 0, 100* > * inHumidity = 0, 100* > * windSpeed = 0, 90* > * pressure = 900, 1100* > * rain=0, 300* > > > > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > For more options, visit https://groups.google.com/d/optout. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.