Hi Ivo,

Re reading your messages, I think I understand the issue - the ws6in1 
driver will back fill missing data but only if it is available from the 
console.  The Bresser 5 in 1 console has a limited storage that gets filled 
and unfortunately once full it no longer stores new data.  If set to 5 
minute recording (which I would recommend) it will stores about 50 days 
worth of data, so you need to periodically empty the buffer (I do this on 
the 1st of the month after backing up the database).  The Bresser 5 in 1 
manual (or at least my copy) seems to have entirely removed the 
instructions on how to set up and clear the data buffer.  I'll add the 
instructions on how to do this to the ws6in1 driver and copy here hopefully 
later today/tomorrow.

Cheers

Bob

On Tuesday, 11 July 2023 at 20:35:11 UTC+1 Ξ wrote:

> also, oops, I've replied to the above but by hitting 'reply to author' so 
> I guess now only Bob sees it :/
>

-- 