I’ve got a metric ton of 3800’s and 2800’s spanning FCS (first customer ship) to less than a month old and have had zero failures.
I agree with one of the other posters that even with no lights displayed, there can be action on the console port. Was the initial failure when connected to a POE switch or using an injector? Cisco switches/injectors or third-party? Jeff From: "[email protected]" <[email protected]> on behalf of Sam Ziadeh <[email protected]> Reply-To: "[email protected]" <[email protected]> Date: Thursday, August 16, 2018 at 7:39 AM To: "[email protected]" <[email protected]> Subject: [WIRELESS-LAN] Cisco AP2800 failure rate Is anyone else seeing a high rate of Cisco AP 2800 failures? Out of a batch of ~500 recently installed Aps, we have had roughly 70 fail. Some were online for a month, but some only a few days. Typically they will fail after a powercycle or loss of power. We are working with Cisco on this, but I’m curious if this is a more wide spread problem. ------------------------------------------------------------- Sam Ziadeh Manager, Network Engineering & Architecture University Networking & Infrastructure Information Technology Services Louisiana State University (225) 578-0074 [email protected]<mailto:[email protected]> ********** Participation and subscription information for this EDUCAUSE Constituent Group discussion list can be found at http://www.educause.edu/discuss. ********** Participation and subscription information for this EDUCAUSE Constituent Group discussion list can be found at http://www.educause.edu/discuss.