Uli DF7SC wrote:
 
> I did again some tests with WSJT-X V1.3r3673. The problem I had 
> with cat control in older versions is still present. When polling 
> interval is not set to zero then sometimes WSJT-X terminates 
> without any notice. This happens often a short time after I change 
> the frequency (in WSJTX or at the rig). When polling interval is set 
> to zero there is no problem.

Tnx info - my polling rate was previously set to 1 - changed to nill.  We'll
see how that goes.

In my case although I have seen the crash when changing the rig frequency
(at the rig, like pressing a band button) my crashes were experienced with
the software running but computer (and rig) otherwise unattended.  WSJT-X
talking to virtual COM port created by microHAM USB Router - talking to
MicroKeyer II interface to FTDX-5000MP.  

Bob W1QA