On 01/03/2017 12:59, Pino Zollo wrote:
> it goes in timeout straight.
>
> ---------------
> icom_init: civ_version=1
> rig_set_conf: civaddr='0x94'
> rig:rig_open called
> Opened rig model 373, 'IC-7300'
> Backend version: 0.7.2, Status: Stable
> Connection opened from localhost:49024
> rigctl(d): 'currVFO' '' '' ''
> rigctl(d): v 'currVFO' '' '' ''
> rigctl(d): v 'currVFO' '' '' ''
> rigctl(d): f 'currVFO' '' '' ''
> write_block(): TX 6 bytes
> 0000    fe fe 94 e0 03 fd                                   ......
> read_string(): Timed out 1.558 seconds after 0 chars
> write_block(): TX 6 bytes
> 0000    fe fe 94 e0 03 fd

HI Pino,

do you have the correct baud rate selected and the correct serial port. 
-s and -r arguments to rigctld.

73
Bill
G4WJS.


------------------------------------------------------------------------------