Hi Bill, In r7058: “Add a user control for Tx Delay, on the Advanced tab” to provide sequencer protection for mast head pre-amps. The maximum value in the spinner was 2secs.
At some point between r7295 and r7312 the maximum was reduced to 0.5s. There is no mention of this change in History. Please could this maximum revert to 2s to provide some flexibility. In Configuration.ui: sbTxDelay.. <property name="maximum”> <double>0.500000000000000</double> — John G4KLA ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ wsjt-devel mailing list wsjt-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wsjt-devel