Hi Bill,

In r7058:  “Add a user control for Tx Delay, on the Advanced tab”  to provide 
sequencer protection for mast head pre-amps.   The maximum value in the spinner 
was 2secs.

At some point between r7295 and r7312 the maximum was reduced to 0.5s.   There 
is no mention of this change in History.   Please could this maximum revert to 
2s to provide some flexibility.

In Configuration.ui:  sbTxDelay..            <property name="maximum”>  
<double>0.500000000000000</double>

— John G4KLA




------------------------------------------------------------------------------