On 01/04/2018 15:33, walt williams wrote:
Shouldn't WSJT read the call sign in the record regardless of where in
the data element the call sign is placed, so long as it is in ADIF format?
Hi Walt,
thanks for reporting this issue, I can confirm it is a defect which will
be fixed shortly. It was erroneously matching a field name like
APP_LoTW_OWNCALL as CALL so was finding the wrong value for your QSO
partner's callsigns. A long standing defect that was revealed by the
LoTW ADIF record ordering. If you do not compile WSJT-X yourself and
need a quick fix; I suggest processing your LoTW ADIF download with
something like ADIF Master (http://www.dxshell.com/adif-master.html) and
deleting the APP_LoTW_OWNCALL field from all records before importing
into WSJT-X.
73
Bill
G4WJS.
------------------------------------------------------------------------------