thanks, will use the work around for now
walt
On Sun, Apr 1, 2018 at 4:39 PM, Bill Somerville <[email protected]>
wrote:
> On 01/04/2018 15:33, walt williams wrote:
>
>> Shouldn't WSJT read the call sign in the record regardless of where in
>> the data element the call sign is placed, so long as it is in ADIF format?
>>
>
> Hi Walt,
>
> thanks for reporting this issue, I can confirm it is a defect which will
> be fixed shortly. It was erroneously matching a field name like
> APP_LoTW_OWNCALL as CALL so was finding the wrong value for your QSO
> partner's callsigns. A long standing defect that was revealed by the LoTW
> ADIF record ordering. If you do not compile WSJT-X yourself and need a
> quick fix; I suggest processing your LoTW ADIF download with something like
> ADIF Master (http://www.dxshell.com/adif-master.html) and deleting the
> APP_LoTW_OWNCALL field from all records before importing into WSJT-X.
>
> 73
> Bill
> G4WJS.
>
>
> ------------------------------------------------------------
> ------------------
> Check out the vibrant tech community on one of the world's most
> engaging tech sites, Slashdot.org! http://sdm.link/slashdot
> _______________________________________________
> wsjt-devel mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/wsjt-devel
>
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
wsjt-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wsjt-devel