On 01/02/2021 15:49, kb8u vhf wrote:
Hello, I have noticed a bug while operating FST4.  I am currently running v2.3.0-rc4 ef3630

To reproduce:

Make a QSO with auto sequencing enabled and RR73 configured to be sent.  While RR73 is being sent, select CQ Next checkbox (expecting to receive 73 from the other station).

After 73 is received, the sequencing incorrectly changes to send 73 instead of sending CQ.

Russ  KB8U

Hi Russ,

what happens in that situation is determined by the "Auto Seq" check box, the "Settings->Reporting->Clear DX call and grid after logging". The "Auto Seq" behaviour will send a 73 message in response to a 73 message unless the QSO is finished by hitting ESC or logging the QSO with the above setting checked.

73
Bill
G4WJS.