The PTT port is no longer shareable by default.
Place this file in C:\Users\[username]\AppData\Local\WSJT-X
{ "config": { "ptt_share": 1 }
}
Mike W9MDB
On Sunday, February 14, 2021, 07:43:47 PM CST, Alex Artieda, HB9DRI
<[email protected]> wrote:
Just to inform you, I found a bug regarding COM port for PTT, it appears in
WSJT-X 2.3 and in 2.4 RC1, let me explain.
I run 4 WSJT-X at the same time, I use Omnirig to control my IC9700 but PTT is
manage via a COM port, this is a must for me to TX first a Sequencer via the
COM port and later TX the radio, I cannot use CAT for PTT, that guarantee me
no RF spikes etc. 4 WSJT-X plus MAP65 plus WSJT10 are all configure to use COM3
for PTT, in this configuration I can TX with ANY of the 6 programs, more
precise I can TX with the program were the decodes or best decode happens,
unfortunate since WSJT-X 2.3 and 2.4RC1 I can TX ONLY with the FIRST program
who opens the PTT COM port, the other ones don’t work and MAP65 give a opening
COM port ERROR, the other WSJT-X simple don’t TX, would be great to fix this
bug because when you run multiple WSJT-X is a must to work with all instance
capable of TX, WSJT-X 2.2.2 works perfect.
To confirm this bug I roll back to 2.2.2 and install 2.3 and later 2.4RC1, the
bug appear in 2.3
73 de Alex, HB9DRI
_______________________________________________
wsjt-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wsjt-devel