The PTT port is no longer shareable by default.
Place this file in C:\Users\[username]\AppData\Local\WSJT-X
{     "config": {            "ptt_share": 1     }
}

Mike W9MDB
 

    On Sunday, February 14, 2021, 07:43:47 PM CST, Alex Artieda, HB9DRI 
<hb9...@emeham.com> wrote:  
 
 
Just to inform you, I found a bug regarding COM port for PTT, it appears in 
WSJT-X 2.3 and in 2.4 RC1, let me explain.

  

I run 4 WSJT-X at the same time, I use Omnirig to control my IC9700 but PTT is 
manage via a COM port, this is a must for me to TX first a Sequencer via the 
COM port and later TX the radio, I cannot use CAT for PTT,  that guarantee me 
no RF spikes etc. 4 WSJT-X plus MAP65 plus WSJT10 are all configure to use COM3 
for PTT, in this configuration I can TX with ANY of the 6 programs, more 
precise I can TX with the program were the decodes or best decode happens, 
unfortunate since WSJT-X 2.3 and 2.4RC1 I can TX ONLY with the FIRST program 
who opens the PTT COM port, the other ones don’t work and MAP65 give a opening 
COM port ERROR, the other WSJT-X simple don’t TX, would be great to fix this 
bug because when you run multiple WSJT-X is a must to work with all instance 
capable of TX, WSJT-X 2.2.2 works perfect.

  

To confirm this bug I roll back to 2.2.2 and install 2.3 and later 2.4RC1, the 
bug appear in 2.3

  

73 de Alex, HB9DRI

  
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel
  
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to