Peter,
I should have pointed out that there are several support pages for W1HKJ 
software, depending on the O/S you are using.  Here is the link for W1HKJ 
website, there are more details there.  
73,Andy, ka2uqw
https://www.w1hkj.org/

    On Sunday, July 27, 2025 at 06:01:54 PM EDT, Peter Sumner via wsjt-devel 
<wsjt-devel@lists.sourceforge.net> wrote:  
 
 Hi Andy, thanks for the link, will have a look there.
Since my original post I have dug deeper and widened my field of testing.   I 
can see on 'other' derivatives of WSJT-X that the rig type is stored as 
"Q65-eme\Configuration\Rig=FLRig FLRig" and not the mangled: Rig="FLRig " I see 
in the current releases of WSJT-X and the Improved version.
It would seem an error has crept into the code base at some point that mangles 
the storage of this parameter when selecting FLRig in the Configuration menu.
Regards,Peter, vk5pj
On Mon, Jul 28, 2025 at 3:07 AM Andrew Neumeier via wsjt-devel 
<wsjt-devel@lists.sourceforge.net> wrote:

 Peter,
I don't know if this is a wjstx issue or a flrig issue.  If you are unable to 
rectify your problem with help from this group, may I suggest posing the 
question to the linuxham group.  I have placed the link below.  That group is 
active and involves the programs created by W1HKJ, including flrig. 
Best of luck,73,Andy, ka2uqw
https://groups.io/g/linuxham




    On Saturday, July 26, 2025 at 09:22:07 PM EDT, Peter Sumner via wsjt-devel 
<wsjt-devel@lists.sourceforge.net> wrote:  
 
 Hi, for some time now (all of the 2.7 variants and now 2.8) when I open WJST-X 
or swap between configurations, I end up with a rig control error and the 
current rig is shown to be "ADAT www.adat.ch" and not the previously selected 
FLRIG setting.
I have learned to live with this for a while and today decided I should report 
this difficulty for evaluation.
I use the FLRIG interface as it lets me see on my PC desktop what the SWR, 
power out and other settings of my two icom rigs as I do a lot of operating 
from the comfort of the house rather than the 50 metre journey to my shack in 
the stables shed.
So far I have tried an empty INI file a few times and the error occurs with 
each iteration of testing I do, where I have set up multiple configurations.
If I leave it as a SINGLE configuration then there is no error seen. Once I add 
a second or more configuration using FLRIG as the rig type I start seeing the 
Rig control error when starting WSJT-X or swapping configurations.
When testing, if I use a direct connection (IC-7610) then I can add multiple 
configurations and not see an error when starting or swapping configs so the 
error seems to be confined to having FLRIG selected as a rig type.
PC is a Windows 10 X64 O/S which is current with all updates.
I have noticed that in the WSJT-X.INI file, that FLRig is shown in there with a 
trailing space and has inverted commas in some instances and in differently in 
other config (quite a puzzle for me), where as other entries are not shown like 
that, here are some examples from my BIG ini file that has about 8 
configurations in it
Rig=Icom IC-7610Rig=FLRig FLRigRig="FLRig "Rig=FLRig IC-7610(FLRig)
hope I have no missed anything, any help would be appreciated
Regards,Peter, vk5pj_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel
  _______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel
  
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to