Ok. I'm getting zero water volume for contacting spheres for an adimensionned 
capillary pressure Pc* =  1500 +/- 5 (the minimum adimensionned water volume 
seems to be ~ 2.6e-6)

Thanks for remarks,

Jerome


________________________________
From: Yade-dev [[email protected]] 
on behalf of Bruno Chareyre [[email protected]]
Sent: November 10, 2014 4:51 AM
To: [email protected]
Subject: Re: [Yade-dev] Some cleaning in capillary law : data files validity

Good point. I think you can consider that the max value of dimensionless Pc is 
the same (at least the order of magnitude) for all possible distances.
When you know this maximum for particles in contact (how much is it by the 
way?) it applies for the other interactions as well.
It is indeed less easy to detect problems algorithmicaly for this case, but 
practically you will get warned as soon as two particles are in contact, which 
will occur in most cases.
As a general rule: if you manipulate saturation degrees of the order of 10e-6 
or so, it should ring a bell.

Bruno