On 10/11/14 20:00, Jerome Duriez wrote: > Ok. I'm getting zero water volume for contacting spheres for an > adimensionned capillary pressure Pc* = 1500 +/- 5 (the minimum > adimensionned water volume seems to be ~ 2.6e-6) > Great. It means that 1500 was probably the max value when generating the data files. There could be a warning in the code if Pc*>=1500, but it is only relevant for a specific set of data files... The max should be defined automatically when reading the data.