On Sep 2, 2007, at 2:16 PM, tobes wrote:

2007-09-02 19:13:01 DEBUG zen.Events: looking up ip 192.168.1.5
2007-09-02 19:13:01 DEBUG zen.Events: ip 192.168.1.5 -> intsw01- Office-2950 2007-09-02 19:13:01 DEBUG zen.Events: Found device=intsw01-IOM- Office-2950 2007-09-02 19:13:01 DEBUG zen.Events: lookup eventClassKey:LINK-3- UPDOWN 2007-09-02 19:13:01 DEBUG zen.Events: match on:/Events/Net/Link/ instances/LINK-3-UPDOWN 2007-09-02 19:13:01 DEBUG zen.Events: regex='Interface (? P<component>\S+), changed state to down' summary='Interface FastEthernet0/1, changed state to up' 2007-09-02 19:13:01 DEBUG zen.Events: match on:/Events/Net/Link/ instances/LINK-3-UPDOWN_ADMIN_DOWN 2007-09-02 19:13:01 DEBUG zen.Events: regex='Interface (? P<component>.+), changed state to Administrative Shutdown' summary='Interface FastEthernet0/1, changed state to up' 2007-09-02 19:13:01 DEBUG zen.Events: match on:/Events/Net/Link/ instances/LINK-3-UPDOWN_UP 2007-09-02 19:13:01 DEBUG zen.Events: regex='Interface (? P<component>.+), changed state to up' summary='Interface FastEthernet0/1, changed state to up'
2007-09-02 19:13:01 DEBUG zen.Events: EventClass:/Net/Link matched

Look at the zProperties for your /Net/Link/LINK-3-UPDOWN-UP event mapping. Look for what the zEventAction and zEventSeverity are set to. The action should be status and the severity should be informational or higher for you to see it by default in the event console.

Are you looking at the dashboard or the event console? Is the intsw01- Office-2950's production state product? If it is anything lower its events will not show on the Dashboard.
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to