Hi Chet,

Thanks for the reply.

How is it that Zenoss decides to use ethernetCsmacd?  how would I choose
another template to be applied by default?

> -----Original Message-----
> From: [EMAIL PROTECTED] 
> [mailto:[EMAIL PROTECTED] On Behalf Of Chet Luther
> Sent: Tuesday, 23 October, 2007 14:48
> To: [email protected]
> Subject: Re: [zenoss-users] confusion regarding templates
> 
> > I have a few divces that have an interface "type" of "Layer 2  
> > Virtual LAN using 802.1Q" yet the ethernetCsmacd template is being  
> > applied to that interface.  I have other interfaces with a "type"  
> > of "ds1" that also have the ethernetCsmacd template applied to  
> > them.  How is Zenoss deciding to apply the ethernetCsmacd template  
> > to those interfaces?
> 
> If you have no template named the same thing as the interface's type  
> the ethernetCsmacd template will be used as the default. If you'd  
> like to setup different monitoring for the "ds1" interface type,  
> create a template named ds1 to override ethernetCsmacd.