Can anyone point me to where the configuration is stored for ZenPing
that causes this event?
I've tried everything I can think of from the GUI with no luck so
I'm thinking that this has been stranded somewhere and just needs to
be deleted.
The configuration for zenping is only stored in the Zope database
(ZEO). Deleting the device and restarting zenping should definitely
have caused this ping even to stop coming back. The only way these
ping events can get into the event console is if zenping tries to ping
the device and doesn't get a response. So we need to figure out why
zenping would continue to try to ping the device even after it is
removed from the system and zenping is restarted.
Try the following steps and let me know what happens.
1. Stop zenping (be sure that it stopped with a ps)
2. Delete the device from the web interface again
3. Start zenping