I tried what you outlined below but, the event still comes right back as soon as I disconnect the device from the network. :(
What do you suggest we try next? Thanks, Eric -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Chet Luther Sent: Monday, November 05, 2007 6:21 AM To: [email protected] Subject: Re: [zenoss-users] Re: Event that always comes back > Can anyone point me to where the configuration is stored for ZenPing > that causes this event? > > I've tried everything I can think of from the GUI with no luck so > I'm thinking that this has been stranded somewhere and just needs to > be deleted. The configuration for zenping is only stored in the Zope database (ZEO). Deleting the device and restarting zenping should definitely have caused this ping even to stop coming back. The only way these ping events can get into the event console is if zenping tries to ping the device and doesn't get a response. So we need to figure out why zenping would continue to try to ping the device even after it is removed from the system and zenping is restarted. Try the following steps and let me know what happens. 1. Stop zenping (be sure that it stopped with a ps) 2. Delete the device from the web interface again 3. Start zenping _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users