I am still not getting alerts on raid even after I fail a drive. At this point I have gone to /Devices/Server/Windows/TestServer --> Clicked on the Drop down menu to the left --> More
--> Templates.

Now under Performance Templates for TestServer I have:

Name:           Definition Path:                                Description:    
Copy:
RaidStatus /Devices/Server/Windows/Devices/TestServer Raid Remove Local Copy

When I click on RaidStatus I have specified each drive providing the OID for each under Data Sources.

Under Thresholds I have specified 1 - 14 Thresholds. Setting the Min and Max to each number for example:

Optimal is the result of 2 so I have setup a Threshold for Optimal setting the Min and Max to 2 and setting the enabled to true. I have binded this templated to this device but I am still not getting any information in my history. Can anyone please tell me what step I am missing.

It sounds like you've done everything correctly. You can try running zenperfsnmp in the foreground with full verbosity on this particular device to see if the SNMP OIDs are being collected and compared to your thresholds.

As the zenoss user:
zenperfsnmp run -v 10 --device=nameOfDeviceInZenoss