cluther:

   Maybe this is where Iv messed up. I perhaps did not RTFM correctly :). So 
far I have created 6 data points. 
        1. OS drive             OID:1.3.6.1.4.1.1597.1.4.1.1.8.0.0.0.0.0
        2. Hot spare            OID:1.3.6.1.4.1.1597.1.4.1.1.8.0.0.4.0.0
        3. Raid Array Drive 1   OID:1.3.6.1.4.1.1597.1.4.1.1.8.0.0.5.0.0
        4. Raid Array Drive 2   OID:1.3.6.1.4.1.1597.1.4.1.1.8.0.0.5.0.1
        5. Raid Array Drive 3   OID:1.3.6.1.4.1.1597.1.4.1.1.8.0.0.6.0.0
        6. Raid Array Drive 4   OID:1.3.6.1.4.1.1597.1.4.1.1.8.0.0.6.0.1

        Each OID can return a number 1 - 14 depending on the status.
And then I created 14 Thresholds:

1       Invalid                 Warning 
2       Optimal                 Info
3       Verifying               Info
4       Failed                  Critical
5       Warning                 Warning
6       Formatting              Info
7       FormatCertifying        Info
8       Missing                 Critical
9       Not Created             Warning
10      Degraded                Critical
11      Building                Info
12      Verify Fixing           Info
13      Abort Activity          Info
14      Reserved                Info

On the first (Invalid) threshold I set my min and max to 1. I done the same on 
each one for example 2 (Optimal) I set the min and max to 2. Do you think this 
is why I am having such a hard time. Did I just not set it up correctly?

Thanks,




-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=14802#14802

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to