Version = Zenoss Core 2.2.3 Virtual Appliance running on a W2k3 Server. When I run a device model for any of our HP/Cisco/Nortel switches I get similar output to the following:-
2008-08-04 10:01:19 INFO zen.Utils Executing command: /home/zenoss/bin/zenmodeler run --now -F -d GOY-HP ProCurve Switch 2610-48 --weblog 2008-08-04 10:01:22 WARNING zen.ZenModeler Reconnected to ZenHub 2008-08-04 10:01:22 INFO zen.ZenModeler collecting for device GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:22 INFO zen.ZenModeler no wmi plugins found for GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:22 INFO zen.ZenModeler no python plugins found for GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:22 INFO zen.ZenModeler no cmd plugins found for GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:22 INFO zen.ZenModeler snmp collection device GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:22 INFO zen.ZenModeler plugins: zenoss.snmp.DeviceMap, zenoss.snmp.InterfaceMap, zenoss.snmp.RouteMap 2008-08-04 10:01:22 INFO zen.ZenModeler no portscan plugins found for GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:23 INFO zen.SnmpClient snmp client finished collection for GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:23 INFO zen.ZenModeler processing zenoss.snmp.DeviceMap for device GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:23 INFO zen.ZenModeler processing zenoss.snmp.InterfaceMap for device GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:23 WARNING zen.ZenModeler skipping 10.13.1.22 points to missing ifindex 101 2008-08-04 10:01:23 WARNING zen.ZenModeler skipping 127.0.0.1 points to missing ifindex 4196 2008-08-04 10:01:23 INFO zen.ZenModeler processing zenoss.snmp.RouteMap for device GOY-HP ProCurve Switch 2610-48 2008-08-04 10:01:24 INFO zen.ZenModeler changes applied 2008-08-04 10:01:24 INFO zen.ZenModeler scan time: 1.83 seconds 2008-08-04 10:01:25 INFO zen.ZenModeler Daemon ZenModeler shutting down 2008-08-04 10:01:25 INFO zen.ZenModeler zenmodeler shutting down 2008-08-04 10:01:25 INFO zen.PerformanceConf configuration collected What is happening when the devices are added is we only get the first 9 switch ports show. Now in previous devices I had issues where traffic and performance would graph but all switch ports showed no in version 2.2.3 I get 9 switch ports and everythign graphs like it should. Is there any quick solution to this? -------------------- m2f -------------------- Read this topic online here: http://community.zenoss.com/forums/viewtopic.php?p=23235#23235 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users