Running Zenoss 2.2.3 on CentOS 5. Added a custom threshold alert according to these instructions (http://www.zenoss.com/Members/cluther/polling-interface-status/) (Thanks for that writeup cluther). Everything was working as expected. Added a few devices and had no issues. Attempted to create my own custom threshold under the ethernetCsmacd template.
Code: Name: Operational Errors Data Points: ifInErrors_ifInErrors, IfOutErrors_ifOutErrors Min Value: 0 Max Value: 0 Event Class: /Perf/Interface Severity: Warning Escalate Count: 3 Enabled: True. With this in place whenever I attempt to add a new device Zenoss fails to create the RRD files. Checking the folder for the files shows only the pickle file. If I delete the device, remove this custom threshold, and then add the device back all the RRD's are created. I am unable to figure out what in this threshold prevents the RRD files from being created. At the end I am looking to have Zenoss log an event when circuit takes errors and to raise and alert when these errors persist for a period of time. -------------------- m2f -------------------- Read this topic online here: http://community.zenoss.com/forums/viewtopic.php?p=23790#23790 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users