feldman wrote: > allright.... > > Is there a way to collect variables other than making a pipe on the > ckeck_http output? > > Another question would be how do you trigger an event from a script in the > GUI? > > Thanks for your help...
You can trigger an event by setting a threshold. Create a new threshold in the 'Performance Template' and select your size Data Point in the multi select list. Set the Min and/or Max value and pick an event class (possibly create your own specific one, which could then initiate an action). Once the size goes over/under that threshold an event gets created. That way you shouldn't really need to compare the previous value with the current one, since you can control an event/action through the threshold. HTH, Jay -------------------- m2f -------------------- Read this topic online here: http://forums.zenoss.com/viewtopic.php?p=30528#30528 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users