mitegen loops might help, particularly micromesh...

JPK

On Fri, May 11, 2012 at 12:35 PM, Rajesh Kumar <ccp4...@hotmail.com> wrote:

>
> Dear Patrick,
>
> You along with others had made some suggestions last time. May be its a
> good time to update.
>
> With classical screening, I got a crystal like appearances/shower with
> HEPES 7.5 and LiSo4 1.5M.  Trying to vary the pH of Hepes or using Tris and
> with different conc of Lithium I could only get very very thin needles
> which shower and difficult to pick even with 0.05 loop. changing conc of
> protein, salt, adding oil on well, changing drop ratio, adding 5% PEGs,
> glycerol, ethylene glycol, didnt reduce shower.
>
>  I prepared the seeds from 7.6 ph and 1.25 M Liso4 conditions and MMS
> screened with all the 4 screens (Qiagen procomplex, classic, peg, JCSG)
> 100nl+100nL+50nL seeds using Phoenix.
>
> Got several nice hits which very good size individual crystals in
> conditions with 30% glycerol and 14% Isopropanol, 20% PEG8K, 30 PEG400.
> When I optimized them I got beautiful crystals and tried at ALS 5.0.3 but
> no spots. I tried picking crystals from 30 min to 4 hrs to 4 days after
> plates were set and there was no luck. Crystals started to appear from 20
> min onwards and keep growing in next couple of hours.  I thought of trying
> dehydration but they were already in dehydrating conditions them selves. I
> wanted to ask if anyone ever failed with MMS but thought not
> waste others time on this. Cross seeding to full length protein and Se met
> protein also gave beautiful crystal but again no diffraction. I have not
> checked SeMet as they were bit small.
>
>  I am still open to ideas if you have any thing on seeding. I did try in
> microbatch and hanging drop as well (1.5 ul protein+ 1.4ul reservor+ 0.4 ul
> seeds, same as sitting drop which gave me very good looking crystals) but I
> didn't get any thing.  I tried streaking with reduced LiSO4 to 1.1 M but
> it didn't give me anything.
>
> Currently, I am making entropy mutations,  new constructs
> of different lengths to solve the above problem.
>
> I still want to improve this condition with needles, because I collected a
> 4.5A data on one of the needle (just one). I need phases. I have sent some
> Iodide soaks to synchotron (yet to collect data) but manipulating these
> crystal drops with more than 100 tiny needles with a tough membrane on it
> has been frustrating as I end up loosing several drops  to just to fish out
> 1-2 needles. I am ready to try   if there any trick left.
>
> Thanks for lots and lots of help.
>
> Regards,
> Rajesh
> ------------------------------
> Date: Fri, 11 May 2012 18:09:54 +0100
> Subject: Re: [ccp4bb] zinc with HEPES
> From: patr...@douglas.co.uk
> To: ccp4...@hotmail.com
>
> Rajesh
>
> How did you do the MMS?  By hand or with a robot, and what screens did you
> use?
>
> and why did you change to HEPES out of interest?
>
> Patrick
>
>
> On 11 May 2012 18:05, Rajesh Kumar <ccp4...@hotmail.com> wrote:
>
>  The rationale was to see if Zn could make differences in crystal
> morphology. This is because the protein has CxxC and CxxH similar to a zinc
> finger motif.
> All my efforts, additive screening, MMS, streaking, micro batch, hanging
> drop, changing drop ratio, drop shape, did not help me to either increase
> thickness  or change the shape of very very thin needle crystals.
> Yes, I will try very less, 50uM.
> Thanks for helping me to understand.
> Rajesh
>
> > Date: Fri, 11 May 2012 12:53:53 -0400
> > Subject: Re: [ccp4bb] zinc with HEPES
> > From: liehy...@gmail.com
> > To: ccp4...@hotmail.com
> >
> > Rajesh,
> > 10mM zinc seems a bit too high. I normally used it at <50uM conc.
> > ray
> >
> > On Fri, May 11, 2012 at 12:26 PM, Rajesh Kumar <ccp4...@hotmail.com>
> wrote:
> > > Dear All,
> > >
> > > This question sounds simple but I dont know the answer.
> > > I was preparing a 24 well crystal screen. When I try to use 10 mM
>  ZnSO4
> > > with HEPES (pH 7.6) buffer it precipitates. I tried both ZnCl2 and Zn
> > > acetate the effect is same.
> > > I dont know why this Zn in not compatible with HEPES.
> > > Could you please tell me why is this?
> > > I appreciate your help.
> > >
> > > Thanks
> > > Rajesh
>
>
>
>
> --
>  patr...@douglas.co.uk    Douglas Instruments Ltd.
>  Douglas House, East Garston, Hungerford, Berkshire, RG17 7HD, UK
>  Directors: Peter Baldock, Patrick Shaw Stewart
>
>  http://www.douglas.co.uk
>  Tel: 44 (0) 148-864-9090    US toll-free 1-877-225-2034
>  Regd. England 2177994, VAT Reg. GB 480 7371 36
>
>


-- 
*******************************************
Jacob Pearson Keller
Northwestern University
Medical Scientist Training Program
email: j-kell...@northwestern.edu
*******************************************

Reply via email to