Hi,
   Let me expalain my network now.
  I have two MGX8850s in India on to which one IPLC each are getting
connected to the PXm1-e1 card.The other end of the IPLC s are connected
similarly to two MGX8850s in UK.
 We have a FRSM card on each of the MGXs .We have 4 cisco 3745 routers
connected using a pair of DTE and DCE cables.

The serial interface is configured for framerelay.I have not created any
subinterfaces on the serial interface for framelrelay. The routers are
configured with HSRP. I would like the HSRP to track the changes in the
status of the IPLC and switch over the HSRP active router. Right now, when
the IPLc goes down, the FRSM card still shows up and the router serial
interfaces shows line protocol up.Thus HSRP , which is tracking the serial
interface still assumes that the link is up and hence will not change the
state.

My objective is :---

 The serial interface connected to the FRSM  on the MGX should be able to
know when the IPLC connected to  PXM1-e1 goes down.And the HSRp which is
tracking the serial interface should change the state .



Thanks and Regards


Diva-
+91-80-98451 41676


                                                                                       
                                                
                     
"Vikram
                      JeetSingh"               To:      
[EMAIL PROTECTED]
                                       Subject:  RE: Query on MGX8850
[7:71702]
                      Sent
by:
                     
[EMAIL PROTECTED]
                     
.com
                                                                                       
                                                
                                                                                       
                                                
                      01/07/2003
18:45
                      Please respond
to
                     
"Vikram
                     
JeetSingh"
                                                                                       
                                                
                                                                                       
                                                



HI Diva,

I think your query is more towards the FR interfaces than the MGX nodes. As
per me, as soon the IPLC or the trunk link on the MGX goes down, it will
also make the FR connection down, and same will be reflected on the PVC
status in router also. So that should serve your purpose, but then what is
your interface configuration, are you using sub-interface or the PVC is
configured on to the main interface itself.  Let us know about your core
objective and some more information, and then may be things take some new
turn.


HTH

Vikram


-----Original Message-----
From: Divakaran Ullampuzhamana [mailto:[EMAIL PROTECTED]
Sent: Tuesday, July 01, 2003 1:27 PM
To: [EMAIL PROTECTED]
Subject: Query on MGX8850 [7:71702]

Hi,
  We have two MGX 8850s to which one IPLC each are connected. The MGX8850
also has a FRSM-HS2 card using which a router is connected to each of the
MGX8850s.
 How do we let the router's serial interface know that the IPLC is down? As
of now , even if the IPLC is down, the serial interface show line protocol
up.
IS there any way by which we can let the Router's serial interface know
that the IPLC connected to the MGX8850 is down?