Hi, Let me expalain my network now. I have two MGX8850s in India on to which one IPLC each are getting connected to the PXm1-e1 card.The other end of the IPLC s are connected similarly to two MGX8850s in UK. We have a FRSM card on each of the MGXs .We have 4 cisco 3745 routers connected using a pair of DTE and DCE cables.
The serial interface is configured for framerelay.I have not created any subinterfaces on the serial interface for framelrelay. The routers are configured with HSRP. I would like the HSRP to track the changes in the status of the IPLC and switch over the HSRP active router. Right now, when the IPLc goes down, the FRSM card still shows up and the router serial interfaces shows line protocol up.Thus HSRP , which is tracking the serial interface still assumes that the link is up and hence will not change the state. My objective is :--- The serial interface connected to the FRSM on the MGX should be able to know when the IPLC connected to PXM1-e1 goes down.And the HSRp which is tracking the serial interface should change the state . Thanks and Regards Diva- +91-80-98451 41676 "Vikram JeetSingh" To: [EMAIL PROTECTED] Subject: RE: Query on MGX8850 [7:71702] Sent by: [EMAIL PROTECTED] .com 01/07/2003 18:45 Please respond to "Vikram JeetSingh" HI Diva, I think your query is more towards the FR interfaces than the MGX nodes. As per me, as soon the IPLC or the trunk link on the MGX goes down, it will also make the FR connection down, and same will be reflected on the PVC status in router also. So that should serve your purpose, but then what is your interface configuration, are you using sub-interface or the PVC is configured on to the main interface itself. Let us know about your core objective and some more information, and then may be things take some new turn. HTH Vikram -----Original Message----- From: Divakaran Ullampuzhamana [mailto:[EMAIL PROTECTED] Sent: Tuesday, July 01, 2003 1:27 PM To: [EMAIL PROTECTED] Subject: Query on MGX8850 [7:71702] Hi, We have two MGX 8850s to which one IPLC each are connected. The MGX8850 also has a FRSM-HS2 card using which a router is connected to each of the MGX8850s. How do we let the router's serial interface know that the IPLC is down? As of now , even if the IPLC is down, the serial interface show line protocol up. IS there any way by which we can let the Router's serial interface know that the IPLC connected to the MGX8850 is down? Thanks and Regards Diva- +91-98451 41676 Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=71771&t=71702 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]