On Sat, Apr 22, 2017 at 07:08:09AM +1200, Chris Packham wrote:
> The ADT7475 and ADT7476 have the STRT bit cleared by default[1]. Before any
> monitoring activities the STRT bit needs to be set. Logically this needs
> to happen before any of the sensors are read so the probe() function
> seems the best place for it.
> 
> [1] - https://www.onsemi.com/pub/Collateral/ADT7475-D.PDF
> 
> Signed-off-by: Chris Packham <chris.pack...@alliedtelesis.co.nz>

Applied.

Thanks,
Guenter

> ---
>  drivers/hwmon/adt7475.c | 13 +++++++++++++
>  1 file changed, 13 insertions(+)
> 
> diff --git a/drivers/hwmon/adt7475.c b/drivers/hwmon/adt7475.c
> index fcfa48222145..c803e3c5fcd4 100644
> --- a/drivers/hwmon/adt7475.c
> +++ b/drivers/hwmon/adt7475.c
> @@ -59,6 +59,8 @@
>  #define REG_VENDID           0x3E
>  #define REG_DEVID2           0x3F
>  
> +#define REG_CONFIG1          0x40
> +
>  #define REG_STATUS1          0x41
>  #define REG_STATUS2          0x42
>  
> @@ -1371,6 +1373,17 @@ static int adt7475_probe(struct i2c_client *client,
>       for (i = 0; i < ADT7475_PWM_COUNT; i++)
>               adt7475_read_pwm(client, i);
>  
> +     /* Start monitoring */
> +     switch (chip) {
> +     case adt7475:
> +     case adt7476:
> +             i2c_smbus_write_byte_data(client, REG_CONFIG1,
> +                                       adt7475_read(REG_CONFIG1) | 0x01);
> +             break;
> +     default:
> +             break;
> +     }
> +
>       ret = sysfs_create_group(&client->dev.kobj, &adt7475_attr_group);
>       if (ret)
>               return ret;