Is this how you would configure the hal?
setp hm2_5i25.0.stepgen.04.steplen 1
setp hm2_5i25.0.stepgen.04.stepspace 1
setp hm2_5i25.0.stepgen.04.step_type2
setp hm2_5i25.0.stepgen.04.control-type 1
setp hm2_5i25.0.stepgen.04.enable 1
setp
On Fri, 27 Jul 2012, Bryce Johnson wrote:
Date: Fri, 27 Jul 2012 11:29:20 -0500
From: Bryce Johnson sie...@gmail.com
Reply-To: Enhanced Machine Controller (EMC)
emc-users@lists.sourceforge.net
To: Enhanced Machine Controller (EMC) emc-users@lists.sourceforge.net
Subject: Re: [Emc-users]
That worked. Thanks Peter!
On Fri, Jul 27, 2012 at 11:44 AM, Peter C. Wallace p...@mesanet.com wrote:
On Fri, 27 Jul 2012, Bryce Johnson wrote:
Date: Fri, 27 Jul 2012 11:29:20 -0500
From: Bryce Johnson sie...@gmail.com
Reply-To: Enhanced Machine Controller (EMC)
On Tue, 2012-07-24 at 20:47 -0700, Peter C. Wallace wrote:
... snip
The latest G540 configuration uses a one output stepgen for the chargepump
due to that rather annoying G540 feature that the chargepump needs a
10 KHz frequency which would force the use of a base thread if the bit was
just
I got a G540 so I switched over the 5i25 firmware to the G540x2. Was there
an XML file for use with pncconf? I did some searching and couldn't come
up with anything. I had used the prob_rfx2 xml with the BOB I had
previously.
Thanks
Bryce
Date: Tue, 24 Jul 2012 17:28:53 -0500
From: sie...@gmail.com
To: emc-users@lists.sourceforge.net
Subject: [Emc-users] xml for G540 and pncconf with 5i25?
I got a G540 so I switched over the 5i25 firmware to the G540x2. Was there
an XML file for use with pncconf? I did some searching
On Wed, 25 Jul 2012, Chris Morley wrote:
Date: Wed, 25 Jul 2012 00:47:48 +
From: Chris Morley chrisinnana...@hotmail.com
Reply-To: Enhanced Machine Controller (EMC)
emc-users@lists.sourceforge.net
To: EMC emc-users@lists.sourceforge.net
Subject: Re: [Emc-users] xml for G540 and