My guess would be that there is a mismatch between the internal label and barcode.
Just a guess though..
Larry Way
408-743-4242 Desk
408-655-3512 Cell
408-743-4201 Fax
>>> [EMAIL PROTECTED] 07/10/01 08:25AM >>>
I've had this happen in the past but this time is different.
I do NOT receive any errors except the following:
ANR8460E AUDIT LIBRARY process for library TEKWOLF failed.
ANR0985I Process 25 for AUDIT LIBRARY running in the
BACKGROUND completed with completion state FAILURE
at
10:09:00.
I printed a q libv list and physically compared it to the Library
inventory, and it matches perfect.
If i run a "audit library tekwolf checklabel=barcode" it completes
successfully. It's when the audit actually mounts the volumes to check the
labels that it fails.
any ideas?
Thanks,
Marc Levitan