At 11:25 AM 7/10/01 -0400, you wrote:
>If i run a "audit library tekwolf checklabel=barcode" it completes
>successfully. It's when the audit actually mounts the volumes to check the
>labels that it fails.
>
>any ideas?
I seem to remember a similar error happening to me. A vendor was in to do
maintenance on the tape library and had inadvertently (!?) changed the scsi
addresses of one of the drives. I've also seen this error when the element
addresses of the drives was incorrect.
Chris
Chris Gibes <[EMAIL PROTECTED]>
Berbee- Milwaukee Branch
N14 W23822 Stone Ridge Dr.
Waukesha, WI 53188
(262) 521-5616
Berbee...putting the E in business