I didnt figure it was an option, just kicking around some ideas On Fri, Jun 28, 2019 at 10:40 AM <[email protected]> wrote:
> You can always add intermediate handholes to break it up into smaller > sections. I have had to rod it before to get it to work, especially around > corners. They make little parachutes to blow jet line through and then > pull mule tape. All sounds reasonable and logical until you actually start > doing it. > > In reality, schedule a maintenance window between 2 and 4 in the morning. > Cut the old fiber and use it to pull in a larger count. > > *From:* Trey Scarborough > *Sent:* Friday, June 28, 2019 9:26 AM > *To:* [email protected] > *Subject:* Re: [AFMUG] 1.25 innerduct capacity > > > yeah I agree with Jim Probably not going to work especial if its been > there for any amount of time. If it it was 24-72 count, typically the same > diameter, maybe if you were blowing it. If this is a build you are planning > and the duct isn't in add another one. > On 6/28/2019 9:19 AM, Jim Bouse [Brazos WiFi] wrote: > > I would be shocked if it works. > > Jim Bouse > Owner - Brazos WiFi > 979-985-5912 > http://www.brazoswifi.com > > > > *From:* AF mailto:[email protected] *On Behalf Of *Steve Jones > *Sent:* Friday, June 28, 2019 9:18 AM > *To:* AnimalFarm Microwave Users Group mailto:[email protected] > *Subject:* Re: [AFMUG] 1.25 innerduct capacity > > > > a mile between handholes > > > > > > On Fri, Jun 28, 2019 at 9:09 AM Jim Bouse [Brazos WiFi] < > [email protected]> wrote: > > In my experience, it is tough to get a second cable through a conduit even > if there is a mule tape. It seems the first cable seems to clog things up. > > We have had limited success inside subdivisions where we have flat drop > cable and running 1 or 2 more flat drops in a conduit. > > > > Jim Bouse > Owner - Brazos WiFi > 979-985-5912 > http://www.brazoswifi.com > > > > *From:* AF <[email protected]> *On Behalf Of *Steve Jones > *Sent:* Friday, June 28, 2019 8:13 AM > *To:* AnimalFarm Microwave Users Group <[email protected]> > *Subject:* [AFMUG] 1.25 innerduct capacity > > > > Pretty sure the answer is no on both, but if i have 1.25 populated with 96 > count, can you realistically come back and blow/pull anything else? What if > its populated with 24 count? > > -- > AF mailing list > [email protected] > http://af.afmug.com/mailman/listinfo/af_af.afmug.com > > > -- > > Trey Scarborough > VP Engineering > 3DS Communications LLC > p:9729741539 > > ------------------------------ > -- > AF mailing list > [email protected] > http://af.afmug.com/mailman/listinfo/af_af.afmug.com > > -- > AF mailing list > [email protected] > http://af.afmug.com/mailman/listinfo/af_af.afmug.com >
-- AF mailing list [email protected] http://af.afmug.com/mailman/listinfo/af_af.afmug.com